Reference-grade measurement accuracy
High-accuracy Venturi reference flow meter according to ISO 5167-3, with accuracy up to ±0.5% of reading.
Reference flow meter for compressors and compressed air billing. Venturi technology according to ISO 5167-3 ensures high accuracy, wide measuring range, and minimal pressure drop.
| Measuring principle Venturi, differential pressure (ISO 5167-3) |
| Accuracy up to ±0.5% of reading |
| Measuring range 1 : 130 |
| Response time < 1 s |
| Media temperature -20 … +100 °C |
| Operating pressure up to 16 bar(g) (optional 30 / 100 bar) |
| Power supply 18 … 36 VDC |
| Outputs / communication 4–20 mA, pulse, Modbus RTU (optional Ethernet/PoE, M-Bus) |
| Measuring principle Venturi, differential pressure (ISO 5167-3) |
| Accuracy up to ±0.5% of reading |
| Measuring range 1 : 130 |
| Response time < 1 s |
| Media temperature -20 … +100 °C |
| Operating pressure up to 16 bar(g) (optional 30 / 100 bar) |
| Power supply 18 … 36 VDC |
| Outputs / communication 4–20 mA, pulse, Modbus RTU (optional Ethernet/PoE, M-Bus) |
| Parameter | DN 50 | DN 80 | DN 100 | DN 125 | DN 150 | DN 200 |
|---|---|---|---|---|---|---|
| Measured medium | Air, gases | |||||
| Measuring principle | Differential pressure, Venturi | |||||
| Measuring range | 1 : 130 | |||||
| Accuracy (0.2 Qmax to Qmax) [%] | ± 0.5 | |||||
| Response time (t99) [s] | < 1 | |||||
| Medium temperature [°C] | -20 … +100 | |||||
| Operating pressure [bar(g)] | max. 16 (optional 30 / 100) | |||||
| Ambient temperature [°C] | -30 … +70 | |||||
| Power supply [VDC] | 18 … 36 | |||||
| Signal outputs (standard) | RS-485 (Modbus RTU), 4–20 mA, pulse output | |||||
| Signal outputs (optional) | Ethernet interface, M-Bus | |||||
High-accuracy Venturi reference flow meter according to ISO 5167-3, with accuracy up to ±0.5% of reading.
A 1:130 measuring range enables reliable measurement of both low and very high flow rates.
Suitable for wet compressed air directly downstream of compressors, as well as dry air consumption measurement.
Venturi technology provides very low pressure drop, reducing system losses and improving energy efficiency.
No moving mechanical parts means no bearing wear and less sensitivity to particles.
Valve block design enables zero adjustment, condensate drain, and calibration sensor replacement under pressure.

Accurate monitoring of compressed air delivery and consumption for cost optimization and internal consumption billing.

Reliable flow measurement for compressor station monitoring, energy analysis, and consistent production quality.

Reference flow measurement for audits, leak-loss reduction, and compressed air system optimization.
Send your basic details and a short project description. We usually respond within 24 hours.
See more flow meter models for different applications:

Thermal flow meter for compressed air and gases with RS-485, 4–20 mA, and pulse outputs.
Več o napravi →
Differential flow meter for wet compressed air or gases with a wide measuring range.
Več o napravi →
High-accuracy Venturi reference flow meter for compressor performance and compressed air billing.