Excellent sensitivity at low velocities
High low-end sensitivity enables accurate measurement from 2 m/s, covering the full operating range of variable-speed (VSD) compressors.
Robust differential-pressure flow sensor for wet compressed air and technical gases, with flow, consumption, temperature, and pressure measurement and installation under pressure.
| Measuring range 2 … 224 m/s / 600 m/s (compressed air) |
| Measuring range (gases) 0.04 … 500 mbar differential pressure |
| Measured medium Air and gases |
| Accuracy ± 1.5% of reading |
| Measuring principle Differential pressure |
| Measuring span 1:100 / 300 |
| Response time t99 < 1 s |
| Media temperature -30 … +180 °C |
| Operating pressure -1 … +100 bar(g) |
| Protection IP67 |
| Outputs RS-485 (Modbus RTU), 4–20 mA, pulse |
| Measuring range 2 … 224 m/s / 600 m/s (compressed air) |
| Measuring range (gases) 0.04 … 500 mbar differential pressure |
| Measured medium Air and gases |
| Accuracy ± 1.5% of reading |
| Measuring principle Differential pressure |
| Measuring span 1:100 / 300 |
| Response time t99 < 1 s |
| Media temperature -30 … +180 °C |
| Operating pressure -1 … +100 bar(g) |
| Protection IP67 |
| Outputs RS-485 (Modbus RTU), 4–20 mA, pulse |
| Parameter | VD 550 |
|---|---|
| Measuring range | 2 … 224 m/s / 600 m/s (compressed air); 0.04 … 500 mbar differential pressure (gases) |
| Measured medium | Air and gases |
| Accuracy | ± 1.5% of reading |
| Measuring principle | Differential pressure |
| Measuring span | 1 : 100 / 300 |
| Response time | t99 < 1 s |
| Medium temperature | –30 … +180 °C |
| Operating pressure | –1 … +100 bar (g) |
| Ambient temperature | –20 … +70 °C |
| Protection class | IP67 |
| Power supply | 18 … 36 V DC, 5 W |
| Output signals (standard) | 1× 4–20 mA analog output (electrically non-isolated), pulse output, RS-485 (Modbus RTU) |
| Output signals (optional) | 2× 4–20 mA active outputs, Ethernet interface (PoE), M-Bus, HART, IO-Link |
High low-end sensitivity enables accurate measurement from 2 m/s, covering the full operating range of variable-speed (VSD) compressors.
The differential-pressure principle enables reliable measurement at very high flow velocities and in large-diameter pipelines.
Flow, total consumption, temperature, and pressure are measured in one instrument for comprehensive system insight.
Suitable for demanding applications with media temperatures up to +180 °C without compromising stability and accuracy.
Applicable in pipelines from DN 20 to DN 1500 for broad use in compressed air and technical gas systems.
Installation via 1/2" or 3/4" ball valve allows mounting and removal without system shutdown.
Impact-resistant die-cast aluminum housing with IP67 protection ensures reliable operation in harsh environments.

Accurate downstream compressor flow measurement for FAD determination, performance tracking, and optimization of fixed-speed and VSD compressor operation.

Used in energy audits and compressed air monitoring, including loss analysis and system optimization.

Reliable flow measurement in large pipelines (DN 20 to DN 1500) and high-velocity industrial processes.
Send your basic details and a short project description. We usually respond within 24 hours.
See more flow meter models for different applications:

Differential flow meter for wet compressed air or gases with a wide measuring range.
Več o napravi →
Robust differential flow meter for wet compressed air and gases in demanding industrial conditions.
Več o napravi →
Inline differential flow meter for larger lines and industrial processes.
Več o napravi →
Highly accurate Venturi flow meter for compressor performance and compressed air billing.
Več o napravi →