CS Instruments – FO 510

Fast and highly accurate measurement of water activity (aw) and temperature in technical oils – independent of oil type or oil age. Optional calculation of absolute water content (ppm) for transformer oils.

Measuring Range: 0…1 aw
Accuracy (0…0.9 aw): ±0.02 aw (at +23 °C)
Accuracy (0.9…1.0 aw): typically ±0.03 aw (at +23 °C)
Process Temperature: 0…125 °C (±0.3 °C)
Pressure Range: up to 300 bar
Interfaces: 2× 4–20 mA + Modbus RTU (RS-485)
Protection: IP66
Measuring Range: 0…1 aw
Accuracy (0…0.9 aw): ±0.02 aw (at +23 °C)
Accuracy (0.9…1.0 aw): typically ±0.03 aw (at +23 °C)
Process Temperature: 0…125 °C (±0.3 °C)
Pressure Range: up to 300 bar
Interfaces: 2× 4–20 mA + Modbus RTU (RS-485)
Protection: IP66
Standard equipment 3 · Options and accessories 6
  • FO 510 – Industrial Oil Moisture SensorIndustrial sensor for measuring water activity (aw) and temperature in technical oils. The standard version includes a stainless-steel housing, M12 (8-pin) connector, IP66 protection, two 4–20 mA analog outputs and Modbus RTU (RS-485).
  • Standard Output ConfigurationAnalog output 1: water activity (aw). Analog output 2: oil temperature (°C). Measurements are independent of oil type and age.
  • Standard Transformer Oil VersionFactory calibration for transformer oil with optional calculation of absolute water content (ppm).
ParameterFO 510
Measuring Range (Water Activity) [aw]0 … 1
Accuracy (0 … 0.9 aw) [aw]±0.02 (at +23 °C)
Accuracy (0.9 … 1.0 aw) [aw]typically ±0.03 (at +23 °C)
Measuring Range (Process Temperature) [°C]0 … 125
Temperature Accuracy [°C]±0.3
Oil Temperature [°C]-20 … +125
Ambient Temperature [°C]-20 … +70
Pressure Range [bar]up to 300
Interfaces2× 4–20 mA analog output (3-wire), Modbus RTU (RS-485)
Power Supply [VDC]24 (10 … 36)
Protection ClassIP66
EMCaccording to DIN EN 61326-1
Thread Material1.4404
Perforated Cap Material1.4301
Electrical ConnectionM12, 8-pin
Installation RecommendationIn a permanent flow-through measuring point (continuous flushing of the measuring point)

Reliable Moisture Monitoring in Technical Oils

Extremely Fast Sensor Response

The FO 510 provides exceptionally fast response to changes in oil moisture content, enabling reliable real-time monitoring and rapid detection of critical conditions.

Accurate Water Activity (aw) Measurement

The sensor measures water activity (aw) with high precision while simultaneously monitoring process temperature. Measurements are independent of oil type and age.

Calculation of Absolute Water Content (ppm)

For transformer oils, direct calculation of absolute water content in ppm is available, providing a clear assessment of insulating oil condition.

Flexible Outputs and Communication

Two freely configurable 4–20 mA analog outputs and a Modbus RTU (RS-485) digital interface ensure easy integration into monitoring and control systems.

Reliable Operation in Demanding Conditions

Industrial-grade construction with IP66 protection enables operation at oil temperatures up to 125 °C and pressures up to 300 bar, even in harsh industrial environments.

Ideal for Technical and Energy Oils

Suitable for measuring residual moisture in transformer, hydraulic, lubricating and engine oils, as well as diesel fuels.

Measuring devices

Tell us what you measure and we will propose the right instrument.

Fill in a short form and we will prepare a proposal for measurement equipment and implementation based on the medium, measuring range, and measurement objective.

Proposal of the right instrument type and measuring range
Measurement reports, trends, and interpretation of results
Supply, installation, calibration, and service
Contact form
* required fields
Your message is sent directly to our email inbox.
Where to find us
Directions
Pod lipami 4 · 1370 Logatec, Slovenija