CS Instruments − FA 515 Ex

Sensor for measuring dew point and pressure dew point in potentially explosive atmospheres. Robust industrial design suitable for pressures up to 500 bar and a wide range of non-aggressive gases.

Measuring Range: −80…+20 °Ctd
Output: 4–20 mA (2-wire technology)
Pressure Range: −1…500 bar
Power Supply: 24 VDC (18…28 VDC)
Protection: IP65
ATEX Approvals: II 2G Ex ib IIC T4 Gb (Zone 1) · II 2D Ex ib IIIC T80°C Db (Zone 21)
Measuring Range: −80…+20 °Ctd
Output: 4–20 mA (2-wire technology)
Pressure Range: −1…500 bar
Power Supply: 24 VDC (18…28 VDC)
Protection: IP65
ATEX Approvals: II 2G Ex ib IIC T4 Gb (Zone 1) · II 2D Ex ib IIIC T80°C Db (Zone 21)
Standard equipment 1 · Options and accessories 5
  • FA 515 Ex – Pressure Dew Point Sensor (ATEX)Standard delivery of the FA 515 Ex sensor for dew point and pressure dew point measurement in potentially explosive atmospheres (4–20 mA analog output). Order no.: 0699 5515.
ParameterFA 515 Ex
Measuring Range [°Ctd]−80 … +20
Output Signal Scaling−80 … +20 °Ctd = 4 … 20 mA
Pressure Range [bar]−1 … 500
Power Supply24 VDC (18 … 28 VDC)
Accuracy (−20 … +20 °Ctd) [°C]± 1
Accuracy (−50 … −20 °Ctd) [°C]± 2
Accuracy (−80 … −50 °Ctd) [°C]± 3
Output4 … 20 mA, 2-wire technology
Protection ClassIP65
EMCAccording to DIN EN 61326-1
Operating Temperature (Dust) [°C]−20 … +50 (II 2D Ex ib IIIC T80°C Db)
Operating Temperature (Gas) [°C]−20 … +70 (II 2G Ex ib IIC T4 Gb)
Storage Temperature [°C]−40 … +80
Analog Output Load [Ω]≤ 300 at 24 V
Process Connection / ThreadG 1/2 (stainless steel 1.4404); optional: UNF 5/8″, NPT 1/2″
Electrical ConnectionM12, 4-pin
Sensor Protection50 μm sintered stainless steel filter
Approval (ATEX – Gas)II 2G Ex ib IIC T4 Gb (Zone 1), intrinsically safe, 135 °C
Approval (ATEX – Dust)II 2D Ex ib IIIC T80°C Db (Zone 21), intrinsically safe, 80 °C
Ex Power Supply Limits (Max.)Ui = 28 V, Ii = 95 mA, Pi = 0.65 W

Reliable Dew Point Measurement in ATEX Areas

ATEX Certification for Hazardous Areas

The sensor is certified for use in Zone 1 (gas) and Zone 21 (dust) and complies with ATEX II 2G Ex ib IIC T4 Gb and II 2D Ex ib IIIC T80°C Db requirements.

Accurate Pressure Dew Point Measurement

Reliably measures dew point and pressure dew point from −80 to +20 °Ctd, enabling effective monitoring of residual moisture in process and gas systems.

Suitable for High Pressures up to 500 bar

The robust pressure-resistant design enables use in high-pressure compressed air and technical gas applications up to 500 bar.

Long-Term Stable Humidity Sensor

A proven sensor with excellent long-term stability ensures reliable measurements and minimal maintenance requirements even in demanding industrial environments.

4–20 mA Output in 2-Wire Technology

The standard 4–20 mA analog output enables easy integration into PLC, monitoring, and SCADA systems within intrinsically safe circuits.

Improved Electronics for Higher Resolution

The new generation of electronics provides higher signal resolution and improved sensor response when measuring very low dew points.

Wide Range of Industrial Gases

Suitable for measurements in compressed air as well as gases such as nitrogen, argon, hydrogen, biogas, and natural gas.

Industrial compressed air systems

Compressed Air

Compressed Air

Dew point monitoring in compressed air systems to prevent condensation, corrosion, and equipment damage, even at high pressures.

Energy systems and industrial processes

Energy Industry

Energy

Moisture monitoring in energy and gas systems where reliable measurements and ATEX compliance are essential for safe operation.

Process industry and dew point measurement

Process Industry

Process

Used in chemical, petrochemical, and other process industries for moisture monitoring in demanding environments with high pressures and explosion risks.

Measuring devices

Tell us what you measure and we will propose the right instrument.

Fill in a short form and we will prepare a proposal for measurement equipment and implementation based on the medium, measuring range, and measurement objective.

Proposal of the right instrument type and measuring range
Measurement reports, trends, and interpretation of results
Supply, installation, calibration, and service
Contact form
* required fields
Your message is sent directly to our email inbox.
Where to find us
Directions
Pod lipami 4 · 1370 Logatec, Slovenija

Dew Point Meters

Choose the right dew point sensor or meter for monitoring residual moisture in compressed air and technical gases. The portfolio includes fixed-installation probes, ATEX versions, and portable service instruments.