Robust IP67 Industrial Housing
The waterproof die-cast aluminum housing ensures reliable operation even in demanding industrial and outdoor environments.
Robust dew point sensor for compressed air and industrial gases, suitable for demanding environments, high pressures, and outdoor installation.
| Dew Point Measuring Range: Up to −80 … +50 °Ctd (depending on version) |
| Accuracy: ±1 … ±3 °C (depending on range) |
| Outputs: 4–20 mA, alarm relay, Modbus RTU |
| Communication (Optional): Ethernet / Modbus TCP, PoE |
| Maximum Pressure: Up to 500 bar (optional) |
| Protection: IP67, aluminum housing |
| Dew Point Measuring Range: Up to −80 … +50 °Ctd (depending on version) |
| Accuracy: ±1 … ±3 °C (depending on range) |
| Outputs: 4–20 mA, alarm relay, Modbus RTU |
| Communication (Optional): Ethernet / Modbus TCP, PoE |
| Maximum Pressure: Up to 500 bar (optional) |
| Protection: IP67, aluminum housing |
| Parameter | FA 550 |
|---|---|
| Device | Dew point / humidity sensor |
| Measuring Range | −80…+20 °Ctd, −60…+30 °Ctd, −20…+50 °Ctd, or 0…100 %RH |
| Accuracy | ±1 °C (+50…−20 °Ctd); ±2 °C (−20…−50 °Ctd); ±3 °C (−50…−80 °Ctd) |
| Pressure Range [bar] | −1…50; special versions up to 350 or 500 |
| Power Supply [VDC] | 24 (10…36) |
| Protection Class | IP67 |
| EMC | According to DIN EN 61326-1 |
| Operating Temperature [°C] | −20…+50 |
| Outputs (Standard) | Modbus RTU (RS-485), active 4–20 mA output (non-isolated), alarm relay (max. 48 VDC, 0.5 A) |
| Output / Bus Options | 2× 4–20 mA (galvanically isolated), Ethernet (Modbus TCP), Ethernet PoE, M-Bus; optional 2–10 V |
| Load (Burden) | < 500 Ω |
| Housing Material | Die-cast aluminum |
| Process Thread | Stainless steel 1.4404; G 1/2", optional UNF 5/8" or 1/2" NPT |
| Display | B1: with integrated display; B2: without display |
| Sensor Protection Cap | F1: sintered stainless-steel cap (~50 μm); F2: perforated stainless-steel cap |
| Surface Finish / Cleaning | Standard; optional oil- and grease-free cleaning (e.g. for oxygen service) or silicone-free version |
| Parameters Available via Modbus | Pressure dew point, temperature, RH, absolute humidity (g/m³), moisture content (g/kg), ppmV/V, water vapor partial pressure (hPa), atmospheric dew point |
The waterproof die-cast aluminum housing ensures reliable operation even in demanding industrial and outdoor environments.
Measures pressure dew point, temperature, relative humidity, absolute humidity, and moisture content in ppm – all in one device.
A very fast sensor response combined with excellent long-term stability ensures reliable monitoring of compressed air and gas quality.
Standard 4–20 mA analog output and alarm relay with configurable threshold and hysteresis for direct integration into control systems.
Support for Modbus RTU and optional Modbus TCP / Ethernet enables seamless integration into SCADA, PLC, and energy monitoring systems.
Versions are available for pressure systems up to 350 bar or even 500 bar, making it ideal for industrial gases and demanding applications.
The integrated display shows dew point in large digits and additional parameters across multiple display pages, with operation via push buttons.
Suitable for dew point monitoring downstream of dryers as well as for gases such as nitrogen, oxygen, hydrogen, argon, natural gas, and biogas.

Continuous dew point monitoring for stable dryer operation and prevention of condensation within the compressed air network.

Monitoring compressed air dryness for reliable pneumatic operation and stable processes in plastics and PET production.

Dew point monitoring to reduce moisture-related risks in processes and support quality requirements in food production.

Accurate dew point monitoring for dry, repeatable conditions and improved traceability in critical production environments.

Monitoring compressed air dryness to ensure reliable operation of systems where air quality is critical.

Dew point monitoring to prevent moisture in instrument air systems and improve equipment reliability.
Fill in a short form and we will prepare a proposal for measurement equipment and implementation based on the medium, measuring range, and measurement objective.
Choose the right dew point sensor or meter for monitoring residual moisture in compressed air and technical gases. The portfolio includes fixed-installation probes, ATEX versions, and portable service instruments.

Compact dew point probe for compressed air and gases, suitable for permanent installation in refrigerated and desiccant dryers.
Learn more→
High-precision dew point probe with an extended measuring range for reliable monitoring of compressed air dryers, improved energy efficiency, and safe system operation.
Learn more→
Robust probe for reliable measurement of dew point and residual moisture in compressed air and industrial gases, even in the most demanding environments.
Learn more→
Dew point probe for hazardous (ATEX) environments, suitable for industrial and process applications.
Learn more→
New-generation dew point sensor for measuring residual moisture in compressed air and gases.
Learn more→
Portable dew point meter with integrated data logger for precise service measurements of dryers down to −80 °Ctd.
Learn more→
All DP 500 functions with an additional free sensor input.
Learn more→
Portable dew point meter with integrated rechargeable battery, high-precision dew point sensor, and pressure sensor up to 16 bar for comprehensive monitoring of moisture and pressure in compressed air systems.
Learn more→