1. Compressors
  2. High-pressure compressors
  3. JAB
JAB – J.A. Becker & SöhneMADE IN GERMANY

J.A. Becker & Söhne · Erlenbach, Germany

JAB
reciprocating compressors

Medium- and high-pressure reciprocating compressors and boosters for air, nitrogen, helium and natural gas – from 20 to 350 bar, with the water-cooled Series 80 up to 410 bar. Compact plug & play units with JABcommand control.

Innovative compressor technology · Lifetime business partner

JAB high-pressure reciprocating compressor with blue fan cowlsince1897
year the company was founded
1897
standard series, Series 80 up to 410 bar
350bar
maximum flow (Series 80)
4,100m³/h
models for air, N₂, He and natural gas
83
Ranges

Seven ranges

Each range has its own page with technical data. The figures below are summarised from the individual model tables.

Medium Pressure
Air · 40–50 bar

Medium Pressure

Two- and three-stage air compressors for starting air, blowing out water turbines and test benches.

Pressure
40–50 bar
Flow
8–181 m³/h
Power
2.2–45 kW
Models
10
Open range
High Pressure
Air · 64–350 bar

High Pressure

Three- and four-stage compressors for test benches, vacuum in HV switchgear and ball-valve actuation.

Pressure
64–350 bar
Flow
13–180 m³/h
Power
4–45 kW
Models
16
Open range
Air Booster MP
Air · inlet 5–13 bar

Air Booster MP

Raises pressure from an existing compressed-air network to 20, 30 or 40 bar – at high flow rates.

Pressure
40 bar
Flow
62–666 m³/h
Power
11–30 kW
Models
4
Open range
Nitrogen
Nitrogen · up to 350 bar

Nitrogen

Gas-tight compressors and boosters for nitrogen from PSA or membrane generators.

Pressure
40–350 bar
Flow
9–182 m³/h
Power
3–45 kW
Models
14
Open range
Helium
Helium · up to 350 bar

Helium

Gas-tight design for helium: pressure-tight crankcase and leak-free shaft seal.

Pressure
40–350 bar
Flow
8–141 m³/h
Power
3–45 kW
Models
12
Open range
CNG
Natural gas · up to 300 bar

CNG

Compressors for natural gas and biogas with inlet pressure from 0.02 bar – for filling stations and test benches.

Pressure
40–300 bar
Flow
8–147 m³/h
Power
1.9–40 kW
Models
13
Open range
CNG Booster
Natural gas · inlet up to 40 bar

CNG Booster

Boosters with 1.5–40 bar inlet pressure for CNG filling stations and biogas injection into the gas grid.

Pressure
20–300 bar
Flow
35–440 m³/h
Power
10–44 kW
Models
14
Open range
83

Not sure which?

The selector compares every model by gas, pressure and flow.

To the selector
Water-cooled · Series 80

JAB Series 80 water-cooled compressors

For air, inert gases, natural gas and biogas, even in difficult rooms and at high ambient temperatures. Pressure-resistant crankcase and oil tank, plasma-nitrided and honed cylinders, and no oil top-up between two services.

Inlet pressure
0–16 bar
Flow
up to 4,100 m³/h
Pressure
up to 410 bar
Stages
1–5
Motor
90–200 kW
Speed
up to 1,500 min⁻¹
JAB “Water Buffalo” V 750/300 NG6 water-cooled natural gas booster

Water Buffalo · V 750/300 NG6Natural gas/biogas, inlet 4–6 bar, 800 m³/h up to 300 bar, 5 stages, 6 cylinders, 160 kW. Presented at ComVac 2017.

Model selector

Which JAB fits your pressure and flow?

Choose the gas, inlet type, final pressure and required flow. The chart shows all 83 models; highlighted are those that reach your pressure and flow without excessive oversizing.

Gas

Inlet

300bar
40m³/h

19 matching models

Flow rates to ISO 1217 at suction. For boosters the flow depends on inlet pressure. We confirm the final choice with a calculation for your case.

Flow versus maximum pressure

2040601001502503505102050100200500Maximum pressure (bar)Flow (m³/h)JAB SV 125/40 · 40 bar · 7.5 m³/hJAB SV 245/40 · 40 bar · 14.7 m³/hJAB SV 500/40 · 40 bar · 30 m³/hJAB SV 600/40 · 40 bar · 36 m³/hJAB SV 700/40 · 40 bar · 45.4 m³/hJAB SV 1000/40 · 40 bar · 59.4 m³/hJAB SV 1100/40 · 40 bar · 66 m³/hJAB SV 1400/40 · 40 bar · 85.8 m³/hJAB SV 2400/50 · 50 bar · 141 m³/hJAB SV 3000/40 · 40 bar · 181.2 m³/hJAB SV 200/64 · 64 bar · 12.9 m³/hJAB SV 1101/64 · 64 bar · 66 m³/hJAB SV 3000/70 · 70 bar · 180 m³/hJAB SV 1101/80 · 80 bar · 66 m³/hJAB SV 2000/80 · 80 bar · 117.9 m³/hJAB SV 1101/120 · 120 bar · 66 m³/hJAB SV 270/150 · 150 bar · 16.2 m³/hJAB SVB 1100/150 · 150 bar · 67.8 m³/hJAB SV 225/350 · 350 bar · 13.1 m³/hJAB SVC 300/350 · 350 bar · 17.4 m³/hJAB SVB 450/250 · 250 bar · 27.3 m³/hJAB SVC 450/350 · 350 bar · 27.3 m³/hJAB SVD 600/350 · 350 bar · 34.5 m³/hJAB SVD 700/350 · 350 bar · 42 m³/hJAB SVB 1100/350 · 350 bar · 64.8 m³/hJAB SVB 1300/350 · 350 bar · 83.4 m³/hJAB V 5345-2/40 · 40 bar · 61.8–154.8 m³/hJAB V 5360-2/40 · 40 bar · 108–207.9 m³/hJAB V 5461-2/40 · 40 bar · 228.6–456 m³/hJAB V 5461-3/40 · 40 bar · 348.9–666 m³/hJAB SV 125/40 He · 40 bar · 7.5 m³/hJAB SV 245/40 He · 40 bar · 14.7 m³/hJAB SV 500/40 He · 40 bar · 30 m³/hJAB SV 1100/40 He · 40 bar · 66 m³/hJAB SV 2400/40 He · 40 bar · 141 m³/hJAB SV 1101/80 He · 80 bar · 66 m³/hJAB SVB 225/250 He · 250 bar · 13.5 m³/hJAB SVC 450/350 He · 350 bar · 27.3 m³/hJAB SVD 600/350 He · 350 bar · 34.5 m³/hJAB SVD 700/350 He · 350 bar · 42 m³/hJAB SVB 1100/350 He · 350 bar · 64.8 m³/hJAB SVB 1300/350 He · 350 bar · 83.4 m³/hJAB SV 125/40 N · 40 bar · 8.6–10.3 m³/hJAB SV 245/40 N · 40 bar · 15.1–17.9 m³/hJAB SV 500/40 N · 40 bar · 32.7–38.6 m³/hJAB SV 1100/40 N · 40 bar · 71.4–84.4 m³/hJAB SV 2400/40 N · 40 bar · 153.9–181.9 m³/hJAB SV 225/350 N · 350 bar · 13.4–18.3 m³/hJAB SVC 450/350 N · 350 bar · 30.8–39.2 m³/hJAB SVD 700/350 N · 350 bar · 46.6–59.3 m³/hJAB SVB 1100/350 N · 350 bar · 72–85.8 m³/hJAB SVB 1300/350 N · 350 bar · 90–108.4 m³/hJAB SVB 1300/350 N1 · 350 bar · 109–145 m³/hJAB V 5635/350 N (4 kW) · 350 bar · 9.2 m³/hJAB V 5635/350 N (5.5 kW) · 350 bar · 12.3 m³/hJAB V 5650/350 N · 350 bar · 30 m³/hJAB SV 125/40 NG · 40 bar · 7.5–9 m³/hJAB SV 200/40 NG · 40 bar · 12–14.4 m³/hJAB SV 245/40 NG · 40 bar · 14.7–17.4 m³/hJAB SV 1100/60 NG · 60 bar · 66–84 m³/hJAB SV 1400/60 NG · 60 bar · 85.2–108.6 m³/hJAB SV 225/300 NG · 300 bar · 13.3–17 m³/hJAB SVC 325/300 NG · 300 bar · 19.5–24.8 m³/hJAB SVC 450/300 NG · 300 bar · 27.2–34.7 m³/hJAB SVD 700/300 NG · 300 bar · 42.8–54.6 m³/hJAB SVB 950/300 NG · 300 bar · 57.4–85.8 m³/hJAB SVB 1100/300 NG · 300 bar · 66.1–84.2 m³/hJAB SVB 1300/300 NG · 300 bar · 85.1–125.1 m³/hJAB SVB 1300/300 NG1 · 300 bar · 116.2–147.2 m³/hJAB V 5650/300 NG6 · 300 bar · 37.7 m³/hJAB V 5660/300 NG4 · 300 bar · 35.1 m³/hJAB V 5740/300 NG40 · 300 bar · 136–189 m³/hJAB V 5760/300 NG16 · 300 bar · 87–161 m³/hJAB V 245/300 NG16 · 300 bar · 129.7–245 m³/hJAB V 5770/300 NG4 · 300 bar · 40–85 m³/hJAB V 5780/300 NG4 · 300 bar · 52–108 m³/hJAB V 5780/300 NG6 · 300 bar · 82–144 m³/hJAB V 5780/300 NG8 · 300 bar · 79–140 m³/hJAB V 200/300 NG8 · 300 bar · 134–206 m³/hJAB V 5790/300 NG3,5 · 300 bar · 66–117 m³/hJAB V 190/300 NG3 · 300 bar · 115.8–186 m³/hJAB V 5780-2/20 NG6 FU · 20 bar · 220 m³/hJAB V 5780-4/20 NG6 FU · 20 bar · 440 m³/h
  • Air
  • Nitrogen
  • Helium
  • Natural gas
  • Booster (pre-pressure)
  • Your requirement
ModelRangePressure (bar)Flow (m³/h)Power (kW)Stages / cylindersInlet (bar)
SVD 700/300 NGCNG30042.8–54.6244 / 40.02–0.3
SVD 700/350High Pressure3504218.54 / 4atmospheric
SVD 700/350 HeHelium35042224 / 4atmospheric
V 5770/300 NG4CNG Booster30040–85304 / 41.5–4
SVD 700/350 NNitrogen35046.6–59.3224 / 40.1–0.4
SVB 950/300 NGCNG30057.4–85.8304 / 40.02–0.3
SVB 1100/300 NGCNG30066.1–84.2304 / 40.02–0.3
V 5780/300 NG4CNG Booster30052–108304 / 41.5–4
Technology

Built for continuous duty

All JAB compressors share the same basis: direct drive, efficient cooling and pressure lubrication. The cutaway shows a high-pressure model.

Cutaway of a JAB high-pressure compressor
  1. Air filterOptimised for flow and sound, with high pre-separation and low pressure drop.
  2. Specially treated cylindersMinimum oil consumption, blow-by and wear.
  3. Direct driveMotor coupled directly to the compressor – no belt losses.
  4. Efficient coolingLow intermediate and outlet temperatures.
  5. Maintenance-free separatorsNo maintenance costs for the separators.
  6. Automatic condensate drainWithout additional solenoid valves.
  7. Quality crank-drive bearingsFor continuous, durable operation.
  8. Pressure lubricationWith oil-pressure monitoring for a long service life.
  9. Three-point mountingVibration-free, no foundation needed.

Gas version

  • Gas-proof shaft seal – no leakage
  • Pressure-tight crankcase, inlet pressure up to 40 bar
  • Pressure switches instead of safety valves – no gas release and less tubing
Control

JABcommand UNI plus

The controller monitors and protects the compressor, automates operation of the unit and simplifies service and maintenance.

  • Error messages in full text and as classic codes, with a large error memory
  • Yellow info LED signals service intervals (gaskets, shaft, pistons)
  • As master control it monitors and operates one or several compressors
  • Switches and push-buttons to EN 60204 for easy operation
  • Rotating-field monitoring and potential-free contacts for integration into a control system
JABcommand UNI plus control panel
Applications

Where JAB compressors work

Fields of application from the JAB brochures, with the ranges we recommend for them.

HV switchgearAir

HV switchgear

Vacuum generation and supply for high-voltage switchgear.

PipelinesAir

Pipelines

Actuation of ball valves in gas and oil pipelines.

CNG filling stationsCNG

CNG filling stations

Filling cars, trucks and buses with natural gas up to 300 bar.

BiogasCNG

Biogas

Compression and injection of biogas into the gas grid.

Thermal deburringCNG

Thermal deburring

Gas for thermal deburring and leakage-gas suction at process gas compressors.

Industrial gasesN₂He

Industrial gases

Nitrogen from PSA and membrane generators, helium for GIT and filling – gas-tight.

Unit and service

Plug & play unit

The compressor comes as an assembled, wired unit on a base frame – KOMP-R takes care of the rest.

Compressor unit

Besides the compressor, the unit usually includes the electric control, inlet and outlet pressure sensors, outlet temperature monitoring, connection hoses and bulkhead fittings. The scope depends on the compressor type.

  • Heating
  • Dryers
  • Filters
  • (High-)pressure storage
  • Fittings
  • Sound-proof hoods

From enquiry to operation

  1. 1
    Selection and sizingWe choose the model and equipment for your gas, inlet and final pressure and flow.
  2. 2
    Acceptance testsIf required, with certification and acceptance at the manufacturer.
  3. 3
    Installation and commissioningSet-up, connection and start-up on site, plus operator training.
  4. 4
    Service and partsRegular service, genuine JAB spare parts and fast response.

KOMP-R – your JAB partner in the region

We advise on selection, supply the unit with equipment and service it throughout its life.

Send an enquiry
Compressors

Tell us your requirements and we will propose the right compressor.

Fill in a short form and we will prepare a configuration proposal.

Sizing based on actual consumption
Energy optimization
Installation and service
Contact form
* required fields
Your message is sent directly to our email inbox.
Where to find us
Directions
Pod lipami 4 · 1370 Logatec, Slovenija