Water chiller
Produces chilled water, typically 7/12 °C, for cooling rooms and equipment. From compact units to screw chillers above 1 MW.
WhenWhen you only need cooling or heat with another source.

MTAIndustrial air conditioning
MTA water chillers, heat pumps and free-cooling modules for production halls, office buildings, hospitals and data centres – from 6.5 to 1,303 kW, including the natural refrigerant R290.
Three kinds of units
All three produce water for the HVAC system – fan coils, air handling units or chilled ceilings. They differ in whether they can also heat and how much energy they use.
Produces chilled water, typically 7/12 °C, for cooling rooms and equipment. From compact units to screw chillers above 1 MW.
WhenWhen you only need cooling or heat with another source.
A reversible unit cools in summer and heats in winter – and produces domestic hot water up to 60–78 °C. One source for the whole year.
WhenWhen you replace a boiler or want cooling and heating from one unit.
When it is colder outside than the return water, the ambient air cools it without a compressor. Works together with a chiller and takes over part or all of the load.
WhenFor year-round cooling – data centres, server rooms, processes.
MTA range
Set the cooling capacity you need and the filters. The series that cover your duty point are shown.
Your requirements
Matching series: 9

Refrigerant: R290
More about the unit
Refrigerant: R410A
More about the unit
More about the unit

Refrigerant: R454B
More about the unit
Refrigerant: R454B
More about the unit
Refrigerant: R454B
More about the unit
Refrigerant: R290
More about the unit
Refrigerant: R290
More about the unit
Refrigerant: R454B
More about the unitNominal values to EN 14511. Actual capacity depends on water and ambient temperatures – we prepare the exact selection for your process.
Technology
An HVAC system runs at part load for most of the year. That is why seasonal efficiency, quiet fans and low-GWP refrigerants matter.
Variable-speed compressors follow the actual demand. At part load they use much less energy and avoid constant cycling.
iCYGNUS N · iCYGNUS G HP · ARIES N iASN
Propane has a GWP of 3 and does not harm the ozone layer. It makes the units ready for the stricter requirements of the F-gas regulation.
iCYGNUS N · ARIES N · ARIES N iASN
Partial or total recovery of condensing heat for domestic hot water or other users – heat that would otherwise be lost to the ambient.
ARIES N · ARIES N iASN · ARIES G · GEMINI G HP
Larger units have two independent circuits with tandem or trio compressors. If one circuit fails, the unit keeps cooling.
ARIES N · ARIES N iASN · ARIES G
Acoustic versions with an insulated compressor compartment and slower EC fans for urban sites, hospitals and hotels.
TAURUS G · ARIES N · ARIES G · iCYGNUS G HP · GEMINI G HP
Modbus RS485, BACnet and Ethernet for integration into the building management system and remote monitoring.
ARIES N · ARIES G · TAURUS G · GEMINI G HP · iCYGNUS G HP · HAEevo Tech
Comparison
Cooling and heating capacity, hot water temperature and refrigerant. Click a series to open its product page.
| Series | Type | Cooling capacity | Heating capacity | Max. hot water | Refrigerant | Compressor | Highlights |
|---|---|---|---|---|---|---|---|
| MTA iCYGNUS N | Heat pump | 6.5–51.8 kW | 8.4–66.3 kW | 78 °C | R290 | scroll | Inverter, Natural refrigerant |
| MTA HAEevo Tech | Heat pump | 12.8–88.4 kW | 11.1–84.3 kW | 55 °C | R410A | scroll | Evaporator-in-tank |
| MTA FC4TAE / FC4ALL | Free-cooler | 18–407 kW | – | – | none (water/glycol) | – | Free-cooling |
| MTA iCYGNUS G HP | Heat pump | 18–49 kW | 23–59 kW | 60 °C | R454B | scroll | Inverter |
| MTA GEMINI G HP | Heat pump | 49.8–116 kW | 54.6–130 kW | 60 °C | R454B | scroll | Low GWP |
| MTA TAURUS G | Water chiller | 72–143 kW | – | – | R454B | scroll | Low GWP |
| MTA ARIES N | Water chiller | 165–240 kW | – | – | R290 | scroll | Inverter, Natural refrigerant |
| MTA ARIES N iASN | Water chiller | 170–320 kW | – | – | R290 | reciprocating (inverter) | Inverter, Low noise |
| MTA ARIES G | Water chiller | 228–1,303 kW | – | – | R454B | screw | Low GWP |
Capacities: nominal range of the series per EN 14511 (cooling 12/7 °C at 35 °C ambient). – = not applicable to this kind of unit or available on request.
Refrigerants
The EU F-gas Regulation (2024/573) is gradually restricting high-GWP refrigerants. For a new system that will run for 15 years or more, the refrigerant is therefore an important decision.
GWP of refrigerants in the MTA range global warming potential, 100 years
TAE N MINI, iCYGNUS N, ARIES N, ARIES N iASN
TAE G, CYGNUS G, NEPTUNE G, ARIES G FC, iCYGNUS G HP, GEMINI G HP, TAURUS G, ARIES G
TAE G Compact, TAE G
TAEevo LWT
TAEevo Tech MINI
TAEevo Tech MINI, TAEevo Tech, TWEevo Tech, HAEevo Tech
GWP values per Regulation (EU) 2024/573, Annex I. Below each refrigerant are the MTA series that use it.
Applications
From production halls to hotels – every building has its own load profile, noise requirements and heating needs.

Cooling of large spaces and air handling units, often combined with process cooling and heat recovery.

Year-round cooling with redundancy and free cooling, which covers a larger share of the load in colder months.

Heat pumps for cooling and heating, fan coils and chilled ceilings, BMS integration.

Reliable air conditioning of operating theatres, laboratories and wards – with two circuits or stand-by units.

Low-noise versions, domestic hot water from the heat pump and heat recovery for pools and wellness.

Inverters for large spaces with strongly varying loads throughout the day and the year.

Smaller high-availability units for server rooms and telecommunication nodes.

R290 heat pumps for heating, cooling and domestic hot water in apartment buildings.
KOMP-R + MTA
A chiller is only part of the system. KOMP-R takes care of the whole – with original parts and MTA factory support.
From your data (kW, temperatures, fluid, operation) we select the series and version, with free-cooling where it pays off.
Pumps, tanks, glycol, pipework and outdoor or indoor installation.
Setting up control, protections and supervision, and handover with operating instructions.
Regular inspections, condenser cleaning, leak checks and fast delivery of spare parts.
FAQ
A water chiller only cools. A heat pump is reversible: it cools in summer, heats in winter, and some versions also produce domestic hot water. If the building is heated by a boiler or district heating, a chiller is enough; when renewing the heating, a heat pump is often the better choice.
We start from the building heat loads – floor area, glazing, occupants, equipment and location – or from the data of the existing system. As a guide, offices often need 60–100 W of cooling per m², but the exact capacity comes from a load calculation.
R290 (propane) has a GWP of 3, so the F-gas regulation does not restrict it the way it restricts synthetic refrigerants. It is very efficient but flammable, which is why MTA uses it in units for outdoor installation with appropriate safety measures.
EER is the ratio of cooling capacity to electrical input at one rating point. SEER covers the whole season, when the unit mostly runs at part load – so it better reflects real running costs. Inverter units have the advantage at part load.
Yes. MTA units support Modbus RS485, and larger series also BACnet and Ethernet. You can monitor them from the BMS and receive alarms remotely.
When you also need cooling in winter – in data centres, server rooms or with a process load. With a higher return water temperature, the number of hours when ambient air is sufficient is high in our climate. We calculate it for your location.
Other division
Process cooling
Chillers for machines, moulds and processes – from 1.7 to 695 kW, down to −24 °C and with ±0.5 °C control. Including a cooling load calculator.
Open divisionAll about MTA industrial cooling
Both divisions, a comparison of all 19 series, free cooling and our services in one place.
Fill in a short form and we will prepare a configuration proposal based on load profile, environment, and energy efficiency goals.