Multiple Measurements in One Device
Measurement of standard volumetric flow, actual volumetric flow, and mass flow using a single device.
Vortex flow meter for steam, gases, and liquids. A highly accurate and versatile flow meter with integrated pressure and temperature compensation.
| Medium: Steam, gases (including mixed gases), liquids |
| Process Temperature: -40 … +350 °C |
| Process Pressure: Up to 63 bar(g) |
| Measurement Principle: Vortex (vortex frequency measurement) |
| Outputs: RS-485 (Modbus RTU), 3× 4–20 mA |
| Options: Ethernet interface |
| Protection: IP67 |
| Material (wetted parts): SS304 stainless steel (SS316 available on request) |
| Medium: Steam, gases (including mixed gases), liquids |
| Process Temperature: -40 … +350 °C |
| Process Pressure: Up to 63 bar(g) |
| Measurement Principle: Vortex (vortex frequency measurement) |
| Outputs: RS-485 (Modbus RTU), 3× 4–20 mA |
| Options: Ethernet interface |
| Protection: IP67 |
| Material (wetted parts): SS304 stainless steel (SS316 available on request) |
| Parameter | DN 15 | DN 20 | DN 25 | DN 32 | DN 40 | DN 50 | DN 65 | DN 80 | DN 100 | DN 125 | DN 150 | DN 200 | DN 250 | DN 300 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Measuring Range | See measuring range table | |||||||||||||
| Measured Medium | Primary single-phase gases, mixed gases, saturated steam, superheated steam, and liquids | |||||||||||||
| Accuracy – Volumetric Flow (gases/steam, Re > 20,000) [% of measured value] | ± 1 | |||||||||||||
| Accuracy – Volumetric Flow (gases/steam, 10,000 < Re < 20,000) [% of measured value] | ± 2 | |||||||||||||
| Accuracy – Volumetric Flow (liquids, Re > 20,000) [% of measured value] | ± 0.75 | |||||||||||||
| Accuracy – Volumetric Flow (liquids, 10,000 < Re < 20,000) [% of measured value] | ± 2 | |||||||||||||
| Accuracy – Mass / Standard Volumetric Flow (gases/steam, Re > 20,000) [% of measured value] | ± 1.5 | |||||||||||||
| Accuracy – Mass / Standard Volumetric Flow (gases/steam, 10,000 < Re < 20,000) [% of measured value] | ± 2.5 | |||||||||||||
| Measurement Principle | Vortex – vortex frequency measurement | |||||||||||||
| Process Temperature [°C] | -40 … +350 | |||||||||||||
| Process Pressure [bar(g)] | up to 63 | |||||||||||||
| Protection Class | IP67 | |||||||||||||
| Measuring Section Material and Wetted Parts | SS304 stainless steel (SS316 available on request) | |||||||||||||
| Display Housing Material | Die-cast aluminum | |||||||||||||
| Signal Outputs (Standard) | RS 485 (Modbus RTU), 3 × 4–20 mA | |||||||||||||
| Signal Outputs (Optional) | Ethernet interface | |||||||||||||
| Power Supply [V DC] | 18 … 36 | |||||||||||||
| Turndown Ratio – Gases | 1 : 30 | |||||||||||||
| Turndown Ratio – Steam | 1 : 35 | |||||||||||||
| Turndown Ratio – Liquids | 1 : 23 | |||||||||||||
| Media Viscosity (DN 15) [mPa·s] | ≤ 4 | |||||||||||||
| Media Viscosity (DN 25) [mPa·s] | ≤ 5 | |||||||||||||
| Media Viscosity (DN 40 … DN 300) [mPa·s] | ≤ 7 | |||||||||||||
| Repeatability [% of measured value] | ± 0.3 | |||||||||||||
| Process Connection | DIN EN 1092-1 flange, ANSI flange, wafer design | |||||||||||||
Measurement of standard volumetric flow, actual volumetric flow, and mass flow using a single device.
Suitable for demanding applications with process temperatures up to 350 °C.
Reliable flow measurement at process pressures up to 63 bar(g).
The flow meter is suitable for unknown or changing gas compositions as well as mixed gases.
All wetted parts are made of stainless steel, ensuring excellent corrosion resistance.
Integrated vibration reference measurement ensures stable and accurate readings even in industrial environments with vibrations.
The flow meter operates without moving parts, resulting in lower wear, higher reliability, and minimal maintenance.

Measurement of saturated and superheated steam for energy monitoring, heat billing, and process efficiency optimization.

Reliable flow measurement of aggressive media, process gases, and liquids in demanding industrial environments.

Steam measurement for cooking, pasteurization, sterilization, and CIP processes in food manufacturing.

Accurate measurement of process and clean steam for validated processes, sterilization, and regulatory compliance.

Measurement of gases and steam at high temperatures and pressures up to 63 bar, including applications with changing media composition.

Monitoring steam, gas, and liquid consumption in production lines to optimize costs and improve energy efficiency.
Fill in a short form and we will prepare a proposal for measurement equipment and implementation based on the medium, measuring range, and measurement objective.
Choose the right flow meter for compressed air, technical gases, steam, or other industrial media. Our portfolio includes thermal, differential pressure, Venturi, and vortex flow meters for a wide range of applications.

New compact inline flow sensor with Bluetooth, IO-Link and PoE, plus optional pressure and dew point measurement.
Learn more→
High-accuracy Venturi flow meter, ideal for compressor monitoring and compressed air consumption billing.
Learn more→
Thermal mass flow meter for compressed air and gases with RS-485, 4–20 mA, and pulse outputs.
Learn more→
Thermal flow meter with integrated measuring section for distribution systems and consumption monitoring.
Learn more→
Robust thermal flow meter for demanding industrial applications, also available with ATEX and DVGW approvals.
Learn more→
Thermal flow meter with a compact measuring section, ideal for consumption monitoring and cost allocation.
Learn more→
Compact inline flow meter for compressed air and gases, suitable for smaller pipelines and machinery.
Learn more→
Compact inline flow meter for compressed air or nitrogen in specialized applications.
Learn more→
Differential pressure flow meter for wet compressed air or gases with a wide measuring range.
Learn more→
Inline differential pressure flow meter with an integrated flow conditioner.
Learn more→
Robust differential pressure flow meter for wet air or gases in demanding industrial environments.
Learn more→
Inline differential pressure flow meter for larger pipelines and industrial processes.
Learn more→
Vortex ultrasonic flow meter for technical and mixed gases, offering high measurement accuracy.
Learn more→
Vortex flow meter for gases, steam, and liquids with integrated pressure and temperature compensation.
Learn more→