CS Instruments – LD 500/510

Fast detection of compressed air and technical gas leaks, with on-site documentation and calculation of leak rates and annual costs.

Minimum Detectable Leak: from 0.1 l/min
On-Site Documentation: integrated camera + data storage
Leak Localization: laser distance measurement + acoustic signal
Reports: ISO 50001 (via software)
Battery Runtime: up to 9 hours
LD 510 Feature: additional sensor input (CS)
Minimum Detectable Leak: from 0.1 l/min
On-Site Documentation: integrated camera + data storage
Leak Localization: laser distance measurement + acoustic signal
Reports: ISO 50001 (via software)
Battery Runtime: up to 9 hours
LD 510 Feature: additional sensor input (CS)
Standard equipment 2 · Options and accessories 5
  • LD 500 SetIncludes: LD 500 leak detector with acoustic horn and integrated camera, 100 leak tags, carrying case, noise-isolating headphones, focus tube with focus tip, AC power adapter, and coiled cable for connecting the ultrasonic sound sensor.
  • LD 510 SetIncludes: LD 510 leak detector with acoustic horn, integrated camera and additional input for external sensors, 100 leak tags, carrying case, noise-isolating headphones, focus tube with focus tip, AC power adapter, and coiled cable for connecting the ultrasonic sound sensor.
ParameterLD 500LD 510
Operating Frequency [kHz]40 ± 2
Connections3.5 mm stereo headphone jack; power socket for external charger
Laser Wavelength [nm]645 … 660
Laser Output Power [mW]< 1 (Class 2)
Display3.5" touchscreen
InterfaceUSB
Data Logger2 GB SD card (100 million values)
Power SupplyIntegrated Li-Ion rechargeable batteries; approximately 9 hours continuous operation; approximately 4 hours charging time
Ambient Temperature [°C]0 … +50
EMCDIN EN 61326
Auto LevelAutomatically adjusts sensitivity to environmental conditions and reliably filters out background noise
Sensitivitymin. 0.1 l/min at 6 bar, distance 5 m; approximately €1/year compressed air cost
External Sensor Input (LD 510 Only)Additional input for connecting external CS sensors
Measuring Range (External Sensor)See the specifications of the connected CS sensor
Accuracy (External Sensor)See the specifications of the connected CS sensor
External Sensor Supply Output Voltage (LD 510) [VDC]—24 ± 10%
External Sensor Supply Output Current (LD 510) [mA]—120 (continuous operation)

Professional Leak Analysis and Energy Loss Assessment

Fast Detection of Even the Smallest Leaks

The device detects even very small leaks (from 0.1 l/min), enabling precise identification and rapid elimination of compressed air or gas losses.

Leak Quantification and Savings Calculation

Displays leak rates (l/min or cfm) and calculates estimated annual losses or potential savings in the selected currency, supporting investment decisions.

Integrated Camera for Documentation

The built-in camera enables leak photography and documentation directly on site. Images are stored together with all relevant leak information.

Auto Level for Stable Detection

The Auto Level function automatically adjusts sensitivity according to environmental conditions and effectively minimizes background noise for more reliable measurements.

ISO 50001 Reporting

The software enables creation of professional ISO 50001-compliant reports for energy audits and leak analysis.

Long Battery Runtime

Up to approximately 9 hours of continuous operation allows a full day of field work without frequent recharging.

Additional Sensors (LD 510 Only)

The LD 510 model includes a universal input for additional CS Instruments sensors such as pressure, flow, temperature, or dew point sensors, significantly expanding its capabilities.

Easy Data Transfer and Analysis

Leak data can be transferred to a computer via USB for detailed analysis and reporting.

General Industry – Compressed Air Systems

General Industry

Energy Efficiency

Detecting leaks in compressed air and industrial gas systems helps reduce energy losses, improve operational reliability, and lower operating costs.

Energy Industry – Monitoring Pressure and Vacuum Systems

Energy

Loss Reduction

Precise leak detection in pressure and vacuum systems contributes to improved energy efficiency, increased safety, and optimized operating costs.

Automotive Industry – Pneumatic Systems

Automotive Industry

Process Quality

Reliable leak detection in pneumatic systems and production lines ensures stable operating conditions, process repeatability, and high product quality.

Measuring devices

Tell us what you measure and we will propose the right instrument.

Fill in a short form and we will prepare a proposal for measurement equipment and implementation based on the medium, measuring range, and measurement objective.

Proposal of the right instrument type and measuring range
Measurement reports, trends, and interpretation of results
Supply, installation, calibration, and service
Contact form
* required fields
Your message is sent directly to our email inbox.
Where to find us
Directions
Pod lipami 4 · 1370 Logatec, Slovenija