High volumetric flow at low pressures
The single-stage F-RER and F-REL radial blowers are designed for applications requiring very high volumetric flow at low differential pressures, in both vacuum and pressure operation.
Radial blowers for vacuum and pressure operation, designed for high volumetric flow at low differential pressures.
| Unit type: Single-stage radial blower |
| Operating mode: Vacuum and positive pressure |
| Volumetric flow: up to 57 m³/min |
| Vacuum: up to 95.5 mbar |
| Positive pressure: up to 99.5 mbar |
| Unit type: Single-stage radial blower |
| Operating mode: Vacuum and positive pressure |
| Volumetric flow: up to 57 m³/min |
| Vacuum: up to 95.5 mbar |
| Positive pressure: up to 99.5 mbar |
| Parameter | RER/REL 260 20 – 0,12 kW | RER/REL 260 20 – 0,20 kW | RER/REL 260 20 – 0,20 kW (1~) | RER/REL 260 50 – 0,37 kW | RER/REL 260 50 – 0,55 kW | RER/REL 320 10 – 0,37 kW | RER/REL 320 20 – 0,32 kW | RER/REL 320 20 – 0,37 kW | RER/REL 320 20 – 0,37 kW (1~) | RER/REL 320 40 – 0,55 kW | RER/REL 320 40 – 0,75 kW | RER/REL 320 50 – 0,75 kW | RER/REL 320 50 – 1,10 kW | RER/REL 350 20 – 0,55 kW | RER/REL 350 20 – 0,55 kW (1~) | RER/REL 350 30 – 0,55 kW | RER/REL 350 30 – 0,75 kW | RER/REL 350 50 – 0,75 kW | RER/REL 350 50 – 1,10 kW | RER/REL 350 50 – 1,50 kW | RER/REL 400 20 – 0,75 kW | RER/REL 400 20 – 1,10 kW | RER/REL 400 50 – 2,20 kW | RER/REL 400 50 – 3,00 kW | RER/REL 440 20 – 0,75 kW | RER/REL 440 20 – 1,10 kW | RER/REL 440 50 – 2,20 kW | RER/REL 440 50 – 3,00 kW | RER/REL 440 50 – 4,00 kW | RER/REL 530 20 – 2,20 kW | RER/REL 530 20 – 3,00 kW | RER/REL 530 50 – 4,00 kW | RER/REL 530 50 – 5,50 kW | RER/REL 620 10 – 2,20 kW | RER/REL 620 10 – 3,00 kW | RER/REL 620 50 – 11,00 kW |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rated motor power [kW] | 0,12 | 0,20 | 0,20 | 0,37 | 0,55 | 0,37 | 0,32 | 0,37 | 0,37 | 0,55 | 0,75 | 0,75 | 1,10 | 0,55 | 0,55 | 0,55 | 0,75 | 0,75 | 1,10 | 1,50 | 0,75 | 1,10 | 2,20 | 3,00 | 0,75 | 1,10 | 2,20 | 3,00 | 4,00 | 2,20 | 3,00 | 4,00 | 5,50 | 2,20 | 3,00 | 11,00 |
| Voltage [V] | 230 Δ / 400 Y | 230 Δ / 400 Y | 1~ 230 V | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 1~ 230 V | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 1~ 230 V | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 220 Δ / 380 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 400 Δ / 690 Y | 230 Δ / 400 Y | 230 Δ / 400 Y | 400 Δ / 690 Y |
| Current [A] | 0,85 Δ / 0,5 Y | 1,2 Δ / 0,7 Y | 1,6 | 1,4 Δ / 0,8 Y | 2,1 Δ / 1,2 Y | 1,9 Δ / 1,1 Y | 1,5 Δ / 0,83 Y | 1,73 Δ / 1,0 Y | 3,0 | 2,1 Δ / 1,2 Y | 3,5 Δ / 2,0 Y | 3,5 Δ / 2,0 Y | 4,6 Δ / 2,65 Y | on request | 4,9 | 2,46 Δ / 1,42 Y | 3,3 Δ / 1,9 Y | 3,5 Δ / 2,0 Y | 4,8 Δ / 2,8 Y | 5,2 Δ / 3,0 Y | 3,0 Δ / 1,8 Y | 5,4 Δ / 3,0 Y | 5,4 Δ / 3,1 Y | 11,8 Δ / 6,8 Y | 3,0 Δ / 1,8 Y | 5,4 Δ / 3,0 Y | 6,6 Δ / 3,8 Y | 11,8 Δ / 6,8 Y | 14,5 Δ / 8,4 Y | 7,1 Δ / 4,1 Y | 12,1 Δ / 7,0 Y | 15,1 Δ / 8,7 Y | 10,3 Δ / 6,0 Y | 9,6 Δ / 5,6 Y | 11,8 Δ / 6,8 Y | 23,0 Δ / 13,3 Y |
| Weight [kg] | 14 | 15 | 18 | 20 | 22 | 22 | 21 | 22 | — | 28 | 30 | 32 | 33 | 30 | 35 | 29 | 30 | 31 | 33 | 36 | 35 | 38 | 45 | 57 | 42 | 43 | 58 | 65 | 84 | 55 | 62 | 70 | 72 | 72 | 75 | 115 |
| Sound level [dB(A)] | 70 | 70 | 70 | 76 | 76 | 72 | 74 | 74 | 74 | 77 | 77 | 81 | 81 | 76 | 76 | 78 | 78 | 81 | 81 | 81 | 78 | 78 | 83 | 83 | 80 | 80 | 84 | 84 | 84 | 81 | 81 | 85 | 85 | 84 | 84 | 87 |
The single-stage F-RER and F-REL radial blowers are designed for applications requiring very high volumetric flow at low differential pressures, in both vacuum and pressure operation.
Different connection configurations and rotation directions are available: right-rotating F-RER and left-rotating F-REL. Horizontal or vertical installation is possible, including motor-up mounting, with or without support feet.
The robust, lightweight construction enables smooth operation with low vibration and low noise, including use in noise-sensitive industrial environments.
Cast-aluminium housings and impellers provide long service life and high operating reliability without the risk of back-contamination of the process.
The bearings are permanently lubricated, so the blowers require no regular maintenance and are ideal for continuous industrial operation.
Versions with a frequency converter enable adjustment of the operating point, energy optimization and precise adaptation to the application.

For air cabinets in printing and finishing machines requiring stable air flow at low differential pressures.

Suitable for extraction systems in woodworking, where high flow is required to remove dust and light particles.

For industrial extraction systems, industrial vacuum cleaners and drying applications where reliable operation and high volumetric flow are important.

For pneumatic conveying of light materials where the application requires high flow and a stable operating point.

For drying and extraction systems in textile production requiring smooth operation and reliable air flow.

For aeration, drying, extraction and wastewater treatment where continuous operation and robustness are important.

For extracting film or plastic edge strips in packaging processes requiring high flow at low pressures.
Fill in a short form and we will prepare a proposal for a vacuum pump or blower based on flow, pressure, and operating conditions. If needed, we can also include filtration, silencers, and accessories.
Explore other vacuum and blower solutions from Elmo Rietschle.

Multi-stage radial blower for vacuum applications. Designed for stable processes and higher vacuum in a compact design, with flow rates up to 8.9 m³/min and vacuum up to 115 mbar.
More about the device→
Multi-stage radial blower for pressure applications. Similar construction to CEV-S, but designed for positive pressure, with flow rates up to 9.3 m³/min and positive pressure up to 125 mbar.
More about the device→
Multi-stage vacuum version with a low filter housing and dust separator for fine material such as paper dust and particles, with flow rates up to 5 m³/min and vacuum up to 90 mbar.
More about the device→
Multi-stage vacuum version with a high filter housing and collection bin for strips and pieces of paper or film, with flow rates up to 7.8 m³/min and vacuum up to 70 mbar.
More about the device→
Single-stage radial blower for vacuum or pressure at low differential pressures. Very high volumetric flow rates up to 57 m³/min; RER rotates right and REL rotates left for easier installation.
More about the device→