Aerial view of the round basins of a municipal wastewater treatment plant
  1. Home
  2. Vacuum & blowers
  3. Robuschi
RobuschiSSI Aeration

Robuschi · Parma, Italy · since 1941

Air for wastewater plants – from blower to bubble

Robuschi is one of the leading makers of oil-free blowers for municipal and industrial wastewater treatment. Lobe, screw, turbo, multistage and side channel blowers cover pressures up to 2,500 mbar(g) and flows up to 70,000 m³/h. Together with SSI Aeration it now also supplies diffusers and membranes – the whole aeration chain from one source.

max. blower pressure
2,500 mbar(g)
max. flow
70,000 m³/h
blowers, vacuum, pumps
23 series
air for biological processes
100% oil-free

01Blower technologies

Five technologies for every duty point

Blower selection comes down to the pressure needed (submergence + losses in piping and diffusers) and the air flow. Robuschi covers the whole range with one brand and one service organisation.

Robox Lobe

Robox Lobe

Rotary lobe blowers

Max. pressure
1,000 mbar(g)
Max. flow
10,500 m³/h

Rugged tri-lobe blowers for constant flow – aeration, grit chambers, filter backwashing and pneumatic conveying.

  • Compact package design
  • Flexible sizing
  • Robust construction
Go to Robox Lobe →
Robox Screw

Robox Screw

Screw blowers

Max. pressure
2,500 mbar(g)
Max. flow
10,100 m³/h

Internal compression for higher pressures and lower energy use than classic lobe blowers – ideal for deep tanks.

  • Up to 30% energy savings
  • Up to 38% smaller footprint
  • Integrated VFD
Go to Robox Screw →
Robox Turbo

Robox Turbo

Turbo blowers

Max. pressure
1,500 mbar(g)
Max. flow
26,500 m³/h

High-speed turbo with PM motor and control for top efficiency under the varying load of the biological stage.

  • Highest efficiency
  • Low noise
  • Plug & play
Go to Robox Turbo →
Robox Multistage

Robox Multistage

Multistage blowers

Max. pressure
1,800 mbar(g)
Max. flow
70,000 m³/h

Multistage centrifugal blowers for the largest treatment plants and very high-flow processes.

  • Maximum capacity
  • Long service life
  • Air and industrial gases
Go to Robox Multistage →
Robox Side Channel

Robox Side Channel

Side channel blowers

Max. pressure
600 mbar(g)
Max. flow
700 m³/h

Oil-free blowers for small flows and low pressures – small plants, channel and tank aeration.

  • Small footprint
  • Maintenance free
  • Low noise
Go to Robox Side Channel →
Robuschi blower operating ranges
Robox Lobeup to 1,000up to 10,500
Robox Screwup to 2,500up to 10,100
Robox Turboup to 1,500up to 26,500
Robox Multistageup to 1,800up to 70,000
Robox Side Channelup to 600up to 700

Pressure on a linear scale, flow on a logarithmic scale. Source: Robuschi Total Blower Capability, 2024.

02Robuschi range

23 series – blowers, vacuum and process pumps

Every Robuschi series supplied by KOMP-R. Click a series for technical data, versions and enquiries.

Process pumps 2

Centrifugal pumps for the chemical and process industries.

03Wastewater plants

Where Robuschi works in a treatment plant

Aeration of the biological stage is the largest power consumer in a wastewater plant. A correctly sized blower with flow control is therefore the fastest route to lower operating costs.

Settling tank at a wastewater treatment plant
50–70%of a plant's energy use goes to aerationSource: SSI Aeration; yet the aeration system is only 1–2% of the investment.
  1. 1

    Grit and grease removal, equalization

    Coarse bubble aeration for mixing, grit separation and preventing anaerobic conditions and odours.

    Suitable series:Robox LobeRobox Side ChannelRobox Direct

  2. 2

    Biological aeration

    Fine bubble aeration of activated sludge. Turbo and screw blowers with DO control follow the daily load swings.

    Suitable series:Robox TurboRobox ScrewRobox MultistageRobox LobeRobox Energy

  3. 3

    Sand filter backwashing

    Short bursts of high air flow for air scouring of filters – the domain of lobe and multistage blowers.

    Suitable series:Robox LobeRobox Multistage

  4. 4

    Aerobic sludge stabilisation

    Aeration of sludge in thickeners and aerobic digesters with high solids content.

    Suitable series:Robox LobeRobox Screw

  5. 5

    Biogas

    ATEX blowers for conveying and boosting biogas from digesters to the gas holder or CHP unit.

    Suitable series:Robox Bio&GasCRBIO / GRBIO

04Robuschi + SSI Aeration

A complete aeration system – from blower to bubble

In February 2025 Ingersoll Rand, owner of the Robuschi brand, acquired SSI Aeration, a US specialist in diffusers and aeration systems. Blower and diffusers now come from the same group – sized together, with one responsible partner.

  1. 1Robuschi blowerOil-free air at the right pressure and flow
  2. 2ControlVariable speed drive and DO-based control
  3. 3SSI pipingPipes, saddles, supports, retrievable grids
  4. 4SSI diffusersDiscs and tubes with PTFE, EPDM or PEEK membranes
Field of SSI disc diffusers in an empty wastewater tank
SSI Aeration

Who is SSI Aeration

SSI was founded in 1995 in Poughkeepsie (New York, USA). It manufactures diffusers in its own plants with robotic assembly, and its engineering team provides process calculations (BioWin), drawings and simulations.

founded, Poughkeepsie, USA
1995
disc diffusers per year
1.1 m
tube diffusers per year
300,000
2015, branches in 6 countries
ISO 9001

SSI fine bubble diffusers

SSI ECD

Disc diffuser

ECD

Single-mold disc diffuser – lower cost for the whole system. Sizes 7", 9", 12" and 20", 3/4" NPT connection.

Air flow 0.2–14 Sm³/h

SSI AFD

Disc diffuser

AFD

Three-piece disc diffuser with replaceable membrane. 9" and 12", also as POD – pre-assembled on pipe.

Air flow 0.75–14 Sm³/h

SSI ECT70

Tube diffuser

ECT70

Single-mold tube diffuser with a “half moon” shape that reduces bubble coalescence. SOTE up to 8%/m, 1 m length.

Air flow 0.7–12 Sm³/h

SSI AFT

Tube diffuser

AFT

Tube diffuser with channel-style support that relieves the membrane in on/off operation. 2" and 3" diameter, saddle for 4" pipe.

Air flow 2.3–30 Sm³/h

Systems and services

Coarse bubble diffusers

AFC75, Relia Ball (non-clogging, for on/off duty) and WBCB in AISI 304 stainless steel – for equalization, grit removal and aerobic digestion, 0–67 Sm³/h.

Retrievable systems

Aeration grids lifted by winch or crane – for plants with a single basin that cannot be drained.

EEVolved MBBR

Biofilm carrier reactor with SSI PTFE aeration: HRT from 2 h, energy from 0.2 kWh/m³.

SSI acid dosing system at the basin edge: tank with containment and dosing pump on a trolley, connected to the air line

Optional equipment

Acid dosing system – clean diffusers while in operation

Over time, inorganic deposits (scale) build up on the membranes. The pores narrow, pressure drop rises and the blower uses more energy – in the very system that accounts for 50–70 % of a treatment plant's energy. The SSI acid dosing system atomizes acid into the air line, the air carries it to every diffuser and the deposits dissolve.

  1. 1
    Containment tank – safe acid storage next to the basin.
  2. 2
    Dosing pump – meters the acid precisely.
  3. 3
    Atomizing nozzle – sprays the acid into the air line upstream of the diffusers.
  4. 4
    Clean diffusers – pores reopen, pressure drop falls.
  • Cleaning without stopping the treatment process
  • No tank draining or diffuser lifting
  • Lower pressure drop – less blower energy
  • Simple routine maintenance instead of manual cleaning

05Membranes

PTFE, EPDM or PEEK – what is the difference?

The membrane is the part of the diffuser that actually forms the bubble. At start-up the materials perform similarly; the difference shows after years in service – in pressure drop, oxygen transfer efficiency (SOTE) and cleaning frequency. The choice of membrane therefore also drives the blower's energy use.

EPDM

Standard elastomer membrane

Colour: black

Synthetic rubber with micro-slits (1 or 2 mm) that open under pressure and close when the air stops, preventing backflow. SSI uses a low-plasticizer compound.

Advantages

  • Lowest price
  • Very good elasticity
  • Proven solution for municipal plants

Watch out for

  • Absorbs liquid and loses plasticizers over time
  • Shrinking and hardening → higher pressure drop
  • Faster biofouling

When to choose: Municipal wastewater without aggressive substances, where capital cost decides.

PTFE

EPDM with patented PTFE coating

Colour: grey

EPDM base with a hydrophobic PTFE (Teflon) coating, patented by SSI in 2004. The coating protects the elastomer from water, chemicals and fouling.

Advantages

  • According to SSI, fouling 5 to 10 times slower than EPDM
  • Slower plasticizer migration
  • Resistance to harsh chemicals

Watch out for

  • Higher initial price than EPDM
  • PTFE is a fluoropolymer (PFAS)

When to choose: Industrial wastewater, fats, chemicals and plants where you want less cleaning and longer life.

PEEK

EPDM with PEEK solid-lubricant coating

Colour: light blue

EPDM base with a PEEK (polyether ether ketone) coating – a high-performance polymer used in bearings and gears. SSI has produced it since 2019.

Advantages

  • Resists biofouling and chemical deposits (scaling)
  • Barrier that locks plasticizers in the membrane
  • Fluorine-free – an alternative to PTFE

Watch out for

  • Newer material, fewer long-term references
  • Price on request

When to choose: Water prone to scaling, or when the client wants to avoid fluoropolymers but needs PTFE-like protection.

Side-by-side comparison
PropertyEPDMPTFEPEEK
ConstructionHomogeneous elastomerEPDM + PTFE coatingEPDM + PEEK coating
SurfaceAbsorbs waterHydrophobic, non-stickSmooth, “self-lubricating”
Fouling and scalingBaseline5–10× slower (SSI)Highly resistant
ChemicalsModerate resistanceHigh resistanceHigh resistance
PlasticizersGradually leach outSlowed migrationLocked in the membrane
Typical useMunicipal wastewaterIndustry, long lifeScaling, fluorine-free
Economical price—
Lifespan—
Municipal wastewater—
Industrial wastewater—

SSI rating (more dots = better). PEEK is not rated in the SSI table – we prepare the data for your project. Silicone and polyurethane membranes are available on request; SSI replacement membranes fit the bodies of most other manufacturers.

Bubble plumes above two disc diffusers compared
Fine bubbles rising above disc diffusers – width of the bubble plume.

06FAQ

Frequently asked questions about Robuschi and SSI

Which Robuschi blower suits wastewater plant aeration?

It depends on pressure and flow. Robox Lobe rotary lobe blowers (up to 1,000 mbar(g)) suit smaller plants and constant flow, Robox Screw screw blowers (up to 2,500 mbar(g)) deeper tanks, Robox Turbo (up to 26,500 m³/h) varying load and maximum efficiency, and Robox Multistage (up to 70,000 m³/h) the largest plants.

Are Robuschi blowers oil-free?

Yes. The compression chamber of Robuschi lobe, screw, turbo, multistage and side channel blowers is oil-free, so the air does not contaminate the biological process.

How are Robuschi and SSI Aeration related?

Both brands are part of Ingersoll Rand, which acquired SSI Aeration in February 2025. Robuschi blowers and SSI diffusers can therefore be sized as one aeration system.

What is the difference between PTFE and EPDM membranes?

EPDM is a standard elastomer that absorbs water and loses plasticizers over time, so it hardens and shrinks, pressure drop rises and efficiency falls. A PTFE membrane has a hydrophobic PTFE coating on an EPDM base that slows plasticizer migration and, according to SSI, reduces fouling 5 to 10 times.

When should I choose a PEEK membrane?

A PEEK coating repels biofilm and chemical deposits and locks in plasticizers, similar to PTFE, but contains no fluorine. It suits water prone to scaling or clients who want to avoid fluoropolymers.

Can we replace only the membranes on existing diffusers?

Yes. SSI replacement membranes in PTFE, PEEK and anti-static EPDM fit the bodies of most diffuser manufacturers. Send us the type and size of your existing diffusers.

Vacuum and blowers

Tell us your requirements and we will propose the right solution.

Fill in a short form and we will prepare a proposal for a vacuum pump or blower based on flow, pressure, and operating conditions. If needed, we can also include filtration, silencers, and accessories.

Technology selection based on the process
Optimization of energy consumption, noise, and maintenance
Supply, installation, commissioning, and service
Contact form
* required fields
Your message is sent directly to our email inbox.
Where to find us
Directions
Pod lipami 4 · 1370 Logatec, Slovenija