High Energy Efficiency
The integrated free-cooling system allows cooling without compressor operation whenever possible, significantly reducing energy consumption and operating costs.
Air-cooled chillers with an integrated free-cooling system for energy-efficient process cooling.
| Cooling Capacity: 160–340 kW |
| Power Supply: 400 V / 3-PE / 50 Hz |
| Refrigerant: R454B |
| Operating Mode: Cooling |
| Compressors: Scroll |
| Heat Exchanger: Shell-and-Tube |
| Fans: EC Axial Fans |
| Cooling Capacity: 160–340 kW |
| Power Supply: 400 V / 3-PE / 50 Hz |
| Refrigerant: R454B |
| Operating Mode: Cooling |
| Compressors: Scroll |
| Heat Exchanger: Shell-and-Tube |
| Fans: EC Axial Fans |
| Parameter | ASG2 FC 065 | ASG2 FC 075 | ASG2 FC 090 | ASG2 FC 105 | ASG2 FC 115 | ASG2 FC 140 |
|---|---|---|---|---|---|---|
| Nominal Cooling Capacity [kW] | 153,87 | 168,61 | 206,34 | 251,31 | 277,26 | 331,08 |
| EER | 2,65 | 2,60 | 2,59 | 2,80 | 2,67 | 2,63 |
| SEPR HT | 5,47 | 5,23 | 5,26 | 5,62 | 5,34 | 5,53 |
| Nominal Free-Cooling Capacity [kW] | 246,40 | 285,20 | 285,20 | 428,20 | 428,20 | 428,30 |
| Power Supply | 400 ± 10 % / 3-PE / 50 | 400 ± 10 % / 3-PE / 50 | 400 ± 10 % / 3-PE / 50 | 400 ± 10 % / 3-PE / 50 | 400 ± 10 % / 3-PE / 50 | 400 ± 10 % / 3-PE / 50 |
| Circuits / Compressors | 2 / 4 | 2 / 4 | 2 / 4 | 2 / 4 | 2 / 4 | 2 / 4 |
| Sound Power Level [dB(A)] | 91 | 93 | 94 | 95 | 96 | 96 |
| Length [mm] | 3091 | 3091 | 3091 | 3439 | 3439 | 3465 |
| Width [mm] | 2191 | 2191 | 2191 | 2191 | 2191 | 2191 |
| Height [mm] | 2424 | 2424 | 2424 | 2424 | 2424 | 2424 |
| Operating Weight [kg] | 1950 | 2047 | 2165 | 2642 | 2699 | 3002 |
The integrated free-cooling system allows cooling without compressor operation whenever possible, significantly reducing energy consumption and operating costs.
Automatic switching between free cooling, partial free cooling, and compressor cooling ensures optimal operation under all ambient temperature conditions.
Reduced compressor operating hours extend equipment lifetime while minimizing maintenance and servicing requirements.
High energy savings provide a rapid payback period and significantly lower long-term operating costs.
The low-GWP R454B refrigerant and reduced refrigerant charge minimize environmental impact while supporting sustainable operation.
The integrated hydraulic module enables fast installation, easy integration into existing systems, and reliable performance in demanding industrial applications.

Precise cooling for plastic injection molding, extrusion, and mold cooling. Stable temperatures ensure higher product quality and repeatable manufacturing processes.

Reliable cooling for production lines, machine tools, and testing systems ensures stable processes and high productivity.

Efficient cooling of reactors, process fluids, and temperature-sensitive applications where accurate temperature regulation is critical.

Cooling of food and beverage production processes while maintaining consistent temperatures to ensure product quality, safety, and compliance with industry standards.

Precise temperature control during wine fermentation and storage to preserve quality, aroma, and product stability.
Fill in a short form and we will prepare a configuration proposal based on load profile, environment, and energy efficiency goals.
Explore the complete range of MTA process chillers – from compact solutions for smaller machines to high-capacity systems for demanding industrial process cooling applications.

Compact industrial chiller using natural R290 refrigerant for precise and reliable cooling of small process applications. It combines high efficiency, robust construction, and simple operation and maintenance.
Learn More→
Compact air-cooled process chiller for water and glycol mixtures. Its minimal footprint, non-ferrous hydraulic circuit, and in-tank evaporator ensure stable process fluid temperatures and reliable operation.
Learn More→
Compact industrial chiller with an integrated hydraulic module and non-ferrous water circuit. Ideal for installation next to machinery or in technical rooms where space is limited.
Learn More→
Air-cooled process chiller with an integrated tank and pump. The in-tank evaporator provides high flow rates, low pressure drops, and stable process temperatures even under varying loads.
Learn More→
Air-cooled industrial process chiller for demanding applications. The integrated pump and tank ensure quick installation, while low-GWP refrigerants provide efficient and sustainable operation.
Learn More→
Specialized air-cooled process chiller designed for cooling glycol mixtures down to −24 °C. Ideal for applications requiring stable low temperatures and reliable continuous operation.
Learn More→
Air-cooled process chiller with scroll compressors and low-GWP R454B refrigerant. The plug-and-play design with an integrated tank and one or two pumps makes it easy to adapt to a wide range of industrial processes.
Learn More→
High-performance process chiller with an integrated free-cooling system. At low ambient temperatures, it reduces compressor operation, energy consumption, and wear on the refrigeration system.
Learn More→
Water-cooled chiller with scroll compressors for medium and large industrial process cooling systems. Its compact footprint, R454B refrigerant, and excellent part-load efficiency make it ideal for demanding technical installations.
Learn More→
Compact water-cooled process chiller with an integrated tank and pump. The in-tank evaporator design ensures low pressure drops, stable process temperatures, and dependable industrial performance.
Learn More→