Environmentally Friendly Refrigerants
The use of low-GWP R513A and R454B refrigerants significantly reduces environmental impact compared to conventional R410A, without compromising efficiency or reliability.
Air-cooled process chillers with scroll compressors for demanding industrial applications and sustainable process cooling.
| Nominal Cooling Capacity: 7–254 kW |
| Power Supply: 400 V / 3 Ph / 50 Hz |
| Refrigerant: R513A / R454B (Low GWP) |
| EER: up to 4.7 (depending on model) |
| Operating Mode: Cooling |
| Heat Exchanger: Tank-Integrated Evaporator |
| Fan: Axial Fans (EC optional) |
| Nominal Cooling Capacity: 7–254 kW |
| Power Supply: 400 V / 3 Ph / 50 Hz |
| Refrigerant: R513A / R454B (Low GWP) |
| EER: up to 4.7 (depending on model) |
| Operating Mode: Cooling |
| Heat Exchanger: Tank-Integrated Evaporator |
| Fan: Axial Fans (EC optional) |
| Parameter | TAE G 020 | TAE G 031 | TAE G 051 | TAE G 071 | TAE G 081 | TAE G 101 | TAE G 121 | TAE G 161 | TAE G 201 | TAE G 251 | TAE G 301 | TAE G 351 | TAE G 381 | TAE G 401 | TAE G 402 | TAE G 502 | TAE G 602 | TAE G 702 | TAE G 802 | TAE G 902 | TAE G 1002 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Nominal Cooling Capacity (1) (12/7 °C, Air 35 °C) [kW] | 4,96 | 7,17 | 10,36 | 16,60 | 21,85 | 25,98 | 33,05 | 35,95 | 43,37 | 47,66 | 57,03 | 64,19 | 75,09 | 85,08 | 87,13 | 99,26 | 112,32 | 130,58 | 148,27 | 171,91 | 190,26 |
| Total Absorbed Power (1) (12/7 °C, Air 35 °C) [kW] | 1,81 | 2,47 | 3,64 | 5,49 | 8,37 | 9,56 | 12,39 | 14,11 | 16,93 | 19,55 | 21,52 | 26,28 | 26,39 | 31,74 | 34,50 | 37,94 | 43,10 | 50,10 | 53,43 | 63,42 | 74,92 |
| EER (1) (12/7 °C, Air 35 °C) | 2,75 | 2,90 | 2,85 | 3,02 | 2,61 | 2,72 | 2,67 | 2,55 | 2,56 | 2,44 | 2,65 | 2,44 | 2,85 | 2,68 | 2,53 | 2,62 | 2,61 | 2,61 | 2,77 | 2,71 | 2,54 |
| Maximum Ambient Temperature (Condition 1) [°C] | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 |
| SEPR HT (2) | 5,11 | 5,20 | 5,10 | 5,20 | 5,09 | 5,15 | 5,01 | 5,05 | 5,64 | 5,60 | 5,28 | 5,36 | 5,46 | 5,56 | 5,49 | 5,69 | 5,61 | 5,61 | 5,86 | 5,63 | 5,36 |
| SEPR MT (3) | 2,85 | 2,95 | 2,92 | 3,17 | 3,27 | 3,11 | 3,29 | 3,39 | 3,31 | 3,36 | 3,27 | 3,38 | 3,36 | 3,34 | 3,42 | 3,55 | 3,58 | 3,64 | 3,80 | 3,67 | 3,61 |
| Nominal Cooling Capacity (4) (20/15 °C, Air 25 °C) [kW] | 7,22 | 10,42 | 14,89 | 23,43 | 30,11 | 35,43 | 45,36 | 48,91 | 59,69 | 65,33 | 78,25 | 87,10 | 103,91 | 117,70 | 121,13 | 137,80 | 155,57 | 175,93 | 197,96 | 229,66 | 254,22 |
| Total Absorbed Power (4) (20/15 °C, Air 25 °C) [kW] | 1,59 | 2,22 | 3,29 | 4,97 | 7,28 | 8,26 | 11,06 | 12,47 | 14,79 | 17,39 | 19,00 | 23,71 | 23,29 | 28,60 | 30,33 | 33,56 | 38,61 | 44,70 | 47,29 | 56,40 | 67,55 |
| EER (4) (20/15 °C, Air 25 °C) | 4,54 | 4,70 | 4,53 | 4,71 | 4,14 | 4,29 | 4,10 | 3,92 | 4,04 | 3,76 | 4,12 | 3,67 | 4,46 | 4,11 | 3,99 | 4,11 | 4,03 | 3,94 | 4,19 | 4,07 | 3,76 |
| Maximum Ambient Temperature (Condition 4) [°C] | 46 | 46 | 46 | 46 | 46 | 46 | 43 | 45 | 45 | 45 | 45 | 44 | 44 | 43 | 44 | 44 | 43 | 43 | 44 | 46 | 45 |
| Power Supply [V / Ph / Hz] | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 | 400 ± 10% / 3-PE / 50 |
| Circuits / Compressors [n°] | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 |
| Sound (5) [dB(A)] | 80,4 | 81,1 | 81,1 | 81,6 | 81,6 | 82,1 | 82,1 | 83,0 | 84,3 | 84,3 | 86,0 | 86,0 | 88,3 | 89,7 | 89,5 | 89,5 | 89,5 | 90,2 | 90,6 | 91,7 | 92,8 |
| Sound (6) [dB(A)] | 52,4 | 53,1 | 53,1 | 53,6 | 53,6 | 54,1 | 54,1 | 55,0 | 56,3 | 56,3 | 58,0 | 58,0 | 60,3 | 61,7 | 61,5 | 61,5 | 61,5 | 62,2 | 62,6 | 78,7 | 79,8 |
| Refrigerant | R513A | R513A | R513A | R513A | R454B | R454B | R454B | R454B | R454B | R454B | R454B | R454B | R454B | R454B | R454B | R454B | R454B | R454B | R454B | R454B | R454B |
| Width [mm] | 560 | 660 | 660 | 761 | 761 | 761 | 761 | 761 | 866 | 866 | 866 | 866 | 1150 | 1150 | 1255 | 1255 | 1255 | 1250 | 1250 | 1250 | 1250 |
| Depth [mm] | 1284 | 1315 | 1315 | 1862 | 1862 | 1862 | 1862 | 1862 | 2250 | 2250 | 2250 | 2250 | 2790 | 2790 | 3298 | 3298 | 3298 | 3535 | 3535 | 4655 | 4655 |
| Height [mm] | 904 | 1420 | 1420 | 1556 | 1556 | 1556 | 1556 | 1556 | 2172 | 2172 | 2172 | 2172 | 2260 | 2260 | 2299 | 2299 | 2299 | 2152 | 2152 | 2152 | 2152 |
| Operating Weight (7) [kg] | 199 | 314 | 324 | 462 | 462 | 624 | 635 | 649 | 924 | 966 | 1018 | 1028 | 1366 | 1419 | 1666 | 1682 | 1726 | 2077 | 2114 | 2839 | 2936 |
| Tank Volume [l] | 60 | 115 | 115 | 140 | 140 | 255 | 255 | 255 | 350 | 350 | 350 | 350 | 410 | 410 | 500 | 500 | 500 | 678 | 678 | 950 | 950 |
| Evaporator Water Connections [Rp-DN] | 3/4" | 1" | 1" | 1 1/2" | 1 1/2" | 1 1/2" | 1 1/2" | 1 1/2" | 2" | 2" | 2" | 2" | 2 1/2" | 2 1/2" | 2 1/2" | 2 1/2" | 2 1/2" | 3" | 3" | 100 | 100 |
The use of low-GWP R513A and R454B refrigerants significantly reduces environmental impact compared to conventional R410A, without compromising efficiency or reliability.
High energy efficiency compliant with the latest ErP Ecodesign requirements for process cooling, verified by Eurovent certification.
Operates with outlet water temperatures from −10 °C to +30 °C and ambient temperatures up to 46 °C, with the possibility of extending the operating range using EC fans.
The integrated hydraulic package with tank and pump enables quick installation, easy commissioning, and immediate readiness for operation.
A wide range of options, kits, and accessories allows the unit to be optimally configured for different industrial processes and specific customer requirements.
Standard safety features include phase monitoring, pressure switches, antifreeze protection, level sensors, and compressor crankcase heaters for long service life and reliable operation.
The galvanized steel enclosure with epoxy powder coating provides excellent mechanical strength, corrosion resistance, and suitability for demanding industrial environments.

Reliable cooling for manufacturing processes in the automotive industry, including metalworking, test lines, welding, paint shops, and cooling circuits for production equipment.

Accurate and stable process cooling for chemical reactions, pharmaceutical manufacturing, laboratories, and production lines where safety, repeatability, and reliability are critical.

Cooling for CNC machines, machining centers, cutting fluids, and hydraulic systems where stable temperatures are essential for maintaining precision and product quality.
Fill in a short form and we will prepare a configuration proposal based on load profile, environment, and energy efficiency goals.
Explore the complete range of MTA process chillers – from compact solutions for smaller machines to high-capacity systems for demanding industrial process cooling applications.

Compact industrial chiller using natural R290 refrigerant for precise and reliable cooling of small process applications. It combines high efficiency, robust construction, and simple operation and maintenance.
Learn More→
Compact air-cooled process chiller for water and glycol mixtures. Its minimal footprint, non-ferrous hydraulic circuit, and in-tank evaporator ensure stable process fluid temperatures and reliable operation.
Learn More→
Compact industrial chiller with an integrated hydraulic module and non-ferrous water circuit. Ideal for installation next to machinery or in technical rooms where space is limited.
Learn More→
Air-cooled process chiller with an integrated tank and pump. The in-tank evaporator provides high flow rates, low pressure drops, and stable process temperatures even under varying loads.
Learn More→
Air-cooled industrial process chiller for demanding applications. The integrated pump and tank ensure quick installation, while low-GWP refrigerants provide efficient and sustainable operation.
Learn More→
Specialized air-cooled process chiller designed for cooling glycol mixtures down to −24 °C. Ideal for applications requiring stable low temperatures and reliable continuous operation.
Learn More→
Air-cooled process chiller with scroll compressors and low-GWP R454B refrigerant. The plug-and-play design with an integrated tank and one or two pumps makes it easy to adapt to a wide range of industrial processes.
Learn More→
High-performance process chiller with an integrated free-cooling system. At low ambient temperatures, it reduces compressor operation, energy consumption, and wear on the refrigeration system.
Learn More→
Water-cooled chiller with scroll compressors for medium and large industrial process cooling systems. Its compact footprint, R454B refrigerant, and excellent part-load efficiency make it ideal for demanding technical installations.
Learn More→
Compact water-cooled process chiller with an integrated tank and pump. The in-tank evaporator design ensures low pressure drops, stable process temperatures, and dependable industrial performance.
Learn More→