Low Environmental Impact
The low-GWP R454B refrigerant significantly reduces environmental impact while ensuring compliance with current and future F-Gas regulations.
Industrial water-to-water chillers and heat pumps with scroll compressors and R454B refrigerant for cooling and process applications in the 50–700 kW range.
| Compressors: Scroll |
| Refrigerant: R454B (GWP 467) |
| Rated Cooling Capacity: 52–695 kW |
| Rated Heating Capacity: 59–792 kW |
| Compressors: Scroll |
| Refrigerant: R454B (GWP 467) |
| Rated Cooling Capacity: 52–695 kW |
| Rated Heating Capacity: 59–792 kW |
| Parameter | 013 | 015 | 019 | 023 | 025 | 029 | 033 | 037 | 041 | 042 | 048 | 056 | 064 | 072 | 078 | 088 | 096 | 162 | 176 | 192 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rated Cooling Capacity [kW] | 52,1 | 59,7 | 66,9 | 79,4 | 91,6 | 108 | 126 | 140 | 152 | 152 | 176 | 208 | 246 | 273 | 297 | 329 | 357 | 596 | 646 | 691 |
| Total Power Input (Cooling) [kW] | 11,0 | 12,9 | 14,6 | 17,4 | 19,5 | 22,7 | 26,4 | 28,8 | 31,8 | 33,3 | 40,7 | 46,1 | 53,6 | 58,2 | 64,4 | 71,6 | 81,0 | 130 | 139 | 151 |
| EER | 4,76 | 4,64 | 4,57 | 4,57 | 4,71 | 4,73 | 4,80 | 4,85 | 4,79 | 4,56 | 4,31 | 4,51 | 4,59 | 4,69 | 4,60 | 4,60 | 4,40 | 4,58 | 4,65 | 4,59 |
| SEER | 6,43 | 6,26 | 6,06 | 6,21 | 6,17 | 6,33 | 6,43 | 6,57 | 6,33 | 5,79 | 5,34 | 5,70 | 5,92 | 6,06 | 5,84 | 6,03 | 5,75 | 6,40 | 6,47 | 6,39 |
| SEPR HT | 9,01 | 8,63 | 8,19 | 8,19 | 8,28 | 8,61 | 8,53 | 8,58 | 8,27 | 7,97 | 7,21 | 7,75 | 7,86 | 7,99 | 7,69 | 7,98 | 7,69 | 8,29 | 8,67 | 8,54 |
| Rated Heating Capacity [kW] | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – |
| Total Power Input (Heating) [kW] | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – |
| COP | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – |
| SCOP (LT) | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – |
The low-GWP R454B refrigerant significantly reduces environmental impact while ensuring compliance with current and future F-Gas regulations.
Optimized scroll compressors, an electronic expansion valve, and advanced control logic provide high EER values and reduced operating costs.
With a cabinet width of only 0.88 m, the unit can be installed even in confined technical rooms while simplifying transport and installation.
Available in HE, HEX, ME, HP, and HP GEO versions, allowing the system to be optimally matched to cooling or heating requirements.
Multiple acoustic versions with optimized airflow and sound insulation ensure quiet operation even in noise-sensitive environments.
Robust construction, proven components, and industrial-grade engineering provide long service life and dependable operation.
The advanced MTA controller ensures precise process water temperature regulation and stable operation under varying load conditions.
Excellent component accessibility, clear diagnostics, and a modular design reduce maintenance time and service costs.

Quiet and stable operation ensures optimal conditions for visitors while protecting sensitive exhibits and technical equipment.

Reliable year-round heating and cooling for hospitality facilities with low operating costs and maximum guest comfort.

An ideal solution for sports halls, wellness centers, and swimming pool complexes where load conditions vary continuously and energy optimization is critical.

Advanced controls ensure reliable air conditioning for modern office buildings with low noise levels and optimized energy consumption.

Suitable for apartment buildings and residential complexes requiring highly efficient and reliable centralized heating and cooling.

High-capacity NEPTUNE G chillers provide uniform temperatures throughout large commercial spaces while ensuring a comfortable shopping experience.
Fill in a short form and we will prepare a configuration proposal based on load profile, environment, and energy efficiency goals.
Explore the complete range of MTA process chillers – from compact solutions for smaller machines to high-capacity systems for demanding industrial process cooling applications.

Compact industrial chiller using natural R290 refrigerant for precise and reliable cooling of small process applications. It combines high efficiency, robust construction, and simple operation and maintenance.
Learn More→
Compact air-cooled process chiller for water and glycol mixtures. Its minimal footprint, non-ferrous hydraulic circuit, and in-tank evaporator ensure stable process fluid temperatures and reliable operation.
Learn More→
Compact industrial chiller with an integrated hydraulic module and non-ferrous water circuit. Ideal for installation next to machinery or in technical rooms where space is limited.
Learn More→
Air-cooled process chiller with an integrated tank and pump. The in-tank evaporator provides high flow rates, low pressure drops, and stable process temperatures even under varying loads.
Learn More→
Air-cooled industrial process chiller for demanding applications. The integrated pump and tank ensure quick installation, while low-GWP refrigerants provide efficient and sustainable operation.
Learn More→
Specialized air-cooled process chiller designed for cooling glycol mixtures down to −24 °C. Ideal for applications requiring stable low temperatures and reliable continuous operation.
Learn More→
Air-cooled process chiller with scroll compressors and low-GWP R454B refrigerant. The plug-and-play design with an integrated tank and one or two pumps makes it easy to adapt to a wide range of industrial processes.
Learn More→
High-performance process chiller with an integrated free-cooling system. At low ambient temperatures, it reduces compressor operation, energy consumption, and wear on the refrigeration system.
Learn More→
Water-cooled chiller with scroll compressors for medium and large industrial process cooling systems. Its compact footprint, R454B refrigerant, and excellent part-load efficiency make it ideal for demanding technical installations.
Learn More→
Compact water-cooled process chiller with an integrated tank and pump. The in-tank evaporator design ensures low pressure drops, stable process temperatures, and dependable industrial performance.
Learn More→